Optical set (optional)

Optical set

Optical stages dedicated for TAS7500TS/TAS7400TS, which achieve spectroscopic measurement (transmittance, reflectance and ATR measurements) and 2D spectroscopy/imaging (mapping) measurement.

Outline Specifications of Spectroscopic Measurement Optical Sets

Can be swiped left or right.
Model SHT-710068 SHT-710193 SHT-710157
Frequency band 2 THz 4 THz 7 THz 2 THz 4 THz 7 THz
Source module TAS1120 TAS1110 TAS1130(*1) TAS1120 TAS1110 TAS1130(*1)
Detector module TAS1220 TAS1230 TAS1230 TAS1220 TAS1230
Mountable measurement module Transmittance, Reflectance Transmittance, Reflectance,
ATR
Transmittance, Reflectance,
ATR
(*2)
Dry air purge cover Not required Not required Required(*3)
Size (W×D×H:mm)(*4) 450 × 220 × 290 450 × 264 × 312 870 × 490 × 220
  1. The NA conversion optical system for spectroscopic measurements (SHT-210101) is required.
  2. Customers should prepare an optical system for measurement.
  3. An acrylic cover is available. Please consult with us separately for detailed specifications.
  4. The heights are the maximum values. They may differ depending on the measurement module to be mounted, etc.

1) Terahertz spectroscopic measurement base for up to 4 THz (2 THz): SHT-710068

2) Terahertz spectroscopic measurement base for up to 7 THz: SHT-710193

  • This optical set can use various spectroscopic measurement modules for terahertz spectroscopic systems TAS7500 SL/SP/SU.
  • It does not require complicated optical adjustments and allows for easy measurement.
  • This compact spectroscopic module does not take time to perform dry air purge for moisture removal.
  • The transmittance module can also perform temperature control measurement by mounting an option (TAS1020/TAS1030).
SHT-710193 with the transmittance module (SHT-2100037) mounted

Spectroscopic measurement modules

Transmittance module
Transmittance polarization analysis module
Reflectance module
ATR module
Temperature control module
(for transmittance modules)
TAS1020/TAS1030

3) Stage for spectroscopic measurement (general-purpose type): SHT-710157

  • This optical set requires customers themselves to form an optical layout.
  • It has a wide sample and jig layout area and also allows measurements using a cryostat, etc.
  • The source and detector optical sections are slidable, which allows arbitrary optical layout for a transmittance or reflectance system, etc. according to the application.
Stage for spectroscopic measurement SHT-710157. The interval between the mirrors can be extended up to 300 millimeters.
Example of a measurement system using a large-sized cryostat

Terahertz Spectroscopy Imaging Optical Set: SHT-710122X04

  • This optical set enables 2D spectroscopy and imaging measurements by scanning samples set on the XY stage.
  • It can perform transmittance and reflectance measurements by switching optical layouts.
  • Spectroscopic measurements of large-sized samples and wide-range spectroscopy and imaging measurements are possible.
  • Using the provided dedicated software enables 2D mapping and spectroscopic analysis at each measurement point.
Photo of the Terahertz Spectroscopy Imaging Optical Set SHT-710122X04.
Example of reflection ratio 2D map of a conductive coating by using SHT-710122X04
Transmittance measurement mode
Reflectance measurement mode
Specifications for SHT-710122X04
Can be swiped left or right.
Model SHT-710122X04(*1)
Frequency band 2 THz 4 THz 7 THz
Source module TAS1120 TAS1110 TAS1130(*2)
Detector module TAS1220 TAS1230
Measurement mode Transmittance and reflectance(*3)
Scan range Max. 150 mm × 150 mm
Scan resolution Min. 0.2 mm
Scan method Raster scan
Measurable sample size Max. 150 mm × 150 mm, Thickness: 45 mm
Measurement time per point(*4) Min. Approx. 1 s (@TAS7500TS, Resolution: 7.6 GHz, Accumulated count 1)
Approx. 2 s (@TAS7400TS, Resolution: 7.6 GHz, Accumulated count 1)
Terahertz spot size < 1 mm(2THz)
< 6 mm(0.3THz)
Measurement position (height) adjustment mechanism in reflectance measurement Stage height Reference height: ± 5 mm (manual)
Terahertz wave light collection height Reference height: 0 to +40 mm (10 mm step)
  1. The following software is required:
    • Spectroscopy and imaging software (STAS14015SE-01)
    • Automatic control license (PYS174-08MNIS or PYS175-08MNIS)
    • Microsoft Excel 64-bit version
  2. The NA conversion optical system for spectroscopy and imaging (SHT-210151) is required.
  3. During reflectance measurement, the angle of incidence is fixed to 10°.
  4. Excluding the sample travel time.